• Electric charge from the body is quickly conducted to specially designed dissipating unit installed on the strap.
• The dissipating unit releases the charge to the humid atmosphere in accordance with "Selglard" principle.
• Cordless operation is not recommended for low humidity environment.
• Band resistivity: 10^3Ω~10^5Ω
Band resistivity
Wrist belt
Individual Packing
<1x105Ω
Adjustable
Blister Card
8PK-611W HOW TO USE?
What is the 8PK-611W, and what is it primarily used for?
The 8PK-611W is a wireless antistatic wrist strap that uses a corona-discharge concept to assist in dissipating accumulated body static without a grounding cord. It supports electronic assembly and general antistatic work where greater freedom of movement is required.
Which users or work situations is the 8PK-611W suitable for?
It is suitable as a portable aid when handling electronic components or performing basic assembly and repair where static risk should be reduced, particularly in higher-humidity environments. High-control ESD production lines must evaluate it against their formal control requirements.
What are the features and benefits of the 8PK-611W's cordless mobility?
The wireless design reduces cord tangling and movement restrictions and is convenient to wear. It does not create a direct equipotential connection to a grounding point and cannot automatically replace a corded wrist strap and grounding system.
What are the features and benefits of skin-contact wear, and how does the environment affect the 8PK-611W?
The inside of the strap must maintain stable skin contact. Perspiration, skin dryness, clothing, and ambient humidity can all affect static dissipation. Each organization should verify performance according to its ESD standard.
How tight should the 8PK-611W be, and where should it be worn?
Wear it on the wrist with the conductive contact surface touching the skin. It should not slip but must not restrict circulation. Do not wear it over a sleeve or glove, and make sure the skin and strap surface are clean before use.
Is the 8PK-611W suitable for highly sensitive ICs or a formal ESD production line?
Suitability depends on the facility's ESD control plan and test results. For highly sensitive components, audited production lines, or low-humidity conditions, a monitored corded grounding strap, work mat, and grounding system are generally preferred.
Can the 8PK-611W be used for energized repair or as an insulating wrist strap?
No. An antistatic wrist strap is not electric-shock protection or electrical insulation. Energized work requires protective tools rated for the voltage, and this wrist strap must not be treated as a safety guarantee.
How should the 8PK-611W be cleaned and inspected?
Clean the contact surface with a soft slightly damp cloth. Avoid strong solvents and immersion, and allow it to dry fully before use. Stop using it if the band becomes loose, the contact surface is damaged, or it fails the organization's ESD verification.
How should I choose between the wireless 8PK-611W and a corded antistatic wrist strap?
The wireless version emphasizes mobility. A corded version connects directly to ground and makes resistance measurement and status monitoring easier. Use a corded system as the primary solution in high-risk or strictly audited environments.
Which operating conditions should be confirmed before purchasing the 8PK-611W?
Confirm the component ESD-sensitivity level, site humidity, company requirements, and validation method. If documents specify grounding resistance or continuous monitoring, a wireless strap alone may not satisfy the requirement.
Shipping Instructions
Ship From
TW
Packing
Blister Card
CTN
200
N.W.
9.5 Kg
G.W.
10.5 Kg
CUFT
2.46
M³
0.07
MOQ
200
Product Inquiry:8PK-611W
Please leave your inquiry and we will contact you as soon as possible.
This site uses cookies. To continue without changing your settings you agree to the use of cookies. Your data will be kept for 6 months.