What is the DP-366A, and what is it primarily used for?
The DP-366A is an extended-length ESD manual desoldering pump measuring approximately 27.5 × 333 mm. Official information specifies suction greater than 38 cm-Hg, making it suitable for multilayer PCBs and larger solder joints.
Which users or work situations is the DP-366A suitable for?
It is suitable for electronic production, repair, and desoldering where static control is required. The ESD design reduces the risk of tool charge but must still be used with a complete grounded antistatic workstation.
What are the features and benefits of the DP-366A's ESD body and long barrel?
The ESD housing supports static control, while the longer barrel provides strong instantaneous suction. Compliance with a facility's required resistance range must still be confirmed from documentation and on-site testing.
What are the features and benefits of the DP-366A's suction greater than 38 cm-Hg?
The strong suction is suitable for multilayer boards and joints with larger amounts of solder, but the solder must first be melted completely. Nozzle distance from the joint also directly affects performance.
What is the correct desoldering procedure for the DP-366A?
De-energize the circuit, cock the pump, melt the solder completely with an iron, position the nozzle close to the molten solder, and trigger it immediately. Add flux if necessary and avoid heating the pad repeatedly for an extended period.
What joint sizes or multilayer boards is the DP-366A suitable for?
Official information positions it for multilayer PCBs and larger joints above approximately 5 mm. Actual performance depends on solder volume, thermal mass, nozzle size, and seal condition.
Can the DP-366A's ESD design replace a grounded wrist strap?
No. An ESD tool is only one part of static control. Operators must still use grounded wrist straps, work mats, grounding points, and environmental monitoring according to site requirements.
How should solder debris be removed from the DP-366A?
After the nozzle has cooled completely, open the collection chamber, remove debris, and inspect the piston, spring, and seals. Prevent solder from blocking the air path and test suction after reassembly.
What is the difference between the DP-366A and DP-366P?
Both are high-suction manual desoldering pumps. The DP-366A emphasizes an extended ESD design, while the DP-366P emphasizes a rear-pull mechanism, non-slip grip, and replaceable nozzle. Select according to ESD requirements and handling preference.
Which points should be confirmed before purchasing the DP-366A?
Confirm the ESD specification, availability of nozzles and seal consumables, suitability of its size for the work space, and the intended market package. For production use, conduct an actual desoldering trial first.
Shipping Instructions
Ship From
SH
Packing
Blister Card
CTN
100
N.W.
13 Kg
G.W.
14 Kg
CUFT
3.16
M³
0.09
MOQ
100
Product Inquiry:DP-366A
Please leave your inquiry and we will contact you as soon as possible.
This site uses cookies. To continue without changing your settings you agree to the use of cookies. Your data will be kept for 6 months.